Technical Information & Details for the Comatec ORH-36-12Y Power Supply
- Output Voltage & Current: 12 V DC (±5%), 0 ~ 3 A (up to 36 W; SELV < 30 V, output over-voltage/open-loop protection < 30 Vp with latch-off)
- Input Voltage Range: 195–265 V AC (230 V AC nominal, 48–63 Hz; typical efficiency approx. 89.5% at 230 V AC full load, no-load power consumption approx. 230 mW)
- Topology & Housing: Flyback switching mode power supply in ORH housing for trunking/junction boxes (e.g., Kaiser art. 1555-XX), no earth connection
- Operating Temperature: −10 °C to +50 °C (storage −40 °C to +80 °C, natural convection cooling with no fan required)
- Protection Circuits: Input overload via two internal fuses, output current limiting & overload/short-circuit protection (HICCUP MODE / auto-restart), over-voltage/open-loop (< 30 Vp, latch-off), high temperature (controller shutdown at 150 °C, auto-restart)
- Wiring & Leads: Input (PRI): Brown/Blue (single insulated with ferrules, approx. 90 ± 10 mm); Output (SEC): Black/Red (double insulated with ferrules, approx. 135 ± 10 mm)
- Dimensions (L x W x H): 53.67 mm x 51.67 mm x 32.0 mm (housing outline dimensions per mechanical drawing)
- Weight: Approx. 150 g
- Safety Class & Protection Index: Class II (when properly installed inside a suitable electrical enclosure meeting PRI/SEC clearances), IP64 (only when using IP64 cable connections), dielectric strength 4242 V DC (60 s), insulation resistance > 4 MΩ, leakage current < 250 µA
- Product Life: > 100,000 hours (at 230 V AC, full load, 30 °C ambient based on electrolytic capacitor life)
- Safety & EMC Standards: CE, EN60335-1, EN55032 Class B, EN61000-3-2 / EN61000-3-3, EN61000-6-2 / EN61000-6-3, EN55024, RoHS (2011/65/EU), ErP (2009/125/EC, Reg. 278/2009)
Information about the Comatec ORH-36-12Y
Designed for installation inside junction and trunking boxes such as Kaiser art. 1555-XX, the Comatec ORH-36-12Y operates as a flyback switching power supply with no earth connection and delivers a 12 V DC output up to 36 W (0–3 A) within SELV limits (< 30 V). Supporting a 195–265 V AC input range (230 V AC nominal, 48–63 Hz) with roughly 89.5% typical efficiency and about 230 mW no-load consumption, it suits continuous building and distribution loads.
Practical installation is aided by pre-fitted leads with ferrules, pairing Brown/Blue input wires (approx. 90 mm, single insulated) with Black/Red output wires (approx. 135 mm, double insulated) for tidy trunking box routing. Furthermore, Class II safety when correctly housed in an electrical enclosure alongside IP64 capability (with IP64 connections) and 4242 V DC dielectric strength supports dependable integration.
System protection is handled through hiccup-mode overload and short-circuit recovery, latch-off protection above < 30 Vp output over-voltage, and over-temperature controller shutdown at 150 °C with auto-restart, backed by dual internal input fuses. Its −10 °C to +50 °C operating temperature range under natural convection without fans works alongside a product life exceeding 100,000 hours at 230 V AC and 30 °C ambient.
Compliance is documented via CE marking and adherence to EN60335-1, EN55032 Class B, EN61000-3-2/-3-3, EN61000-6-2/-6-3, EN55024, RoHS (2011/65/EU), and ErP (2009/125/EC), while final EMC verification remains required in the end equipment. Always verify exact model ratings against the Comatec CE1035 specification and the specific 12 V variant documentation before deployment.