Technical Information & Details for the MEAN WELL QP-150-3A Power Supply
- Rated Output Power (max.): 146 W
- DC Output Voltages (CH1 / CH2 / CH3 / CH4): 5 V / 3.3 V / 12 V / 24 V DC
- Rated Output Currents (CH1 / CH2 / CH3 / CH4): 10 A / 10 A / 2.5 A / 1 A
- Output Current Ranges (CH1 / CH2 / CH3 / CH4): 3–15 A / 0.4–5 A / 0.4–3 A / 0–1 A
- Output Voltage Adjustment Range (CH1): 4.75–5.5 V DC
- Ripple & Noise (max.): CH1: 100 mVp-p, CH2: 100 mVp-p, CH3: 150 mVp-p, CH4: 150 mVp-p
- Input Voltage Range: 90–264 V AC / 127–370 V DC, 47–63 Hz
- Power Factor (typ.): PF > 0.95 @ 230 V AC / PF > 0.98 @ 115 V AC (full load)
- Efficiency (typ.): 73%
- Inrush Current (typ.): Cold start ≤ 40 A @ 230 V AC
- Leakage Current: < 3.5 mA @ 240 V AC
- Hold-Up Time (typ.): 24 ms at full load (115 V AC / 230 V AC)
- Protections: Overload (105–150%, hiccup mode with auto recovery), Over voltage (CH1: 5.75–6.75 V, shut down), Over temperature (option, shut down with auto recovery)
- Working Temperature Range: −10 °C to +60 °C (refer to derating curve)
- Storage Temp. & Humidity: −20 °C to +85 °C, 10–95% RH non-condensing
- Vibration Resistance: 10–500 Hz, 2G, 10 min./cycle, 60 min. each along X, Y, and Z axes
- Cooling: Forced air cooling by built-in DC fan (fixed switching frequency at 100 kHz)
- Withstand & Isolation Specs: I/P–O/P: 3 kV AC, I/P–FG: 2 kV AC, O/P–FG: 0.5 kV AC; Isolation resistance ≥ 100 MΩ @ 500 V DC
- MTBF: 1,763.3k hrs min. (Telcordia SR-332) / 262.6k hrs min. (MIL-HDBK-217F at 25 °C)
- Safety & EMC Standards: UL 60950-1, TÜV BS EN/EN 62368-1, EAC TP TC 004, BS EN/EN 55032 (CISPR 32) Class B, BS EN/EN 61000-3-2/-3, BS EN/EN 61000-4-2 through -11, BS EN/EN 55035, EAC TP TC 020
- Dimensions (L x W x H) & Weight: 199 x 99 x 50 mm / 0.93 kg
- Manufacturer Warranty: 3 years
Information about the MEAN WELL QP-150-3A
Delivering four regulated rails at 5 V, 3.3 V, 12 V, and 24 V inside a 199 x 99 x 50 mm chassis allows the MEAN WELL QP-150-3A to replace multiple standalone converters in compact hardware. Rated up to 146 W maximum output power, it pairs a 4.75–5.5 V adjustable 5 V rail (3–15 A range) with dedicated channels rated for 10 A, 2.5 A, and 1 A. Operating at a fixed 100 kHz switching frequency with a 24 ms hold-up time at full load helps keep multi-rail electronics steady.
Equipment exposed to ongoing mechanical motion and electrical noise benefits from tested vibration resistance of 10–500 Hz at 2G along X, Y, and Z axes for dependable structural stability. At the same time, a 3 kV AC input-to-output withstand voltage paired with 100 MΩ minimum isolation resistance at 500 V DC provides clear electrical separation. Hiccup-mode overload protection (105–150%) with automatic recovery and CH1 over-voltage shutdown help protect connected loads during fault events.
Broad regulatory readiness is supported by UL 60950-1, TÜV BS EN/EN 62368-1, and EAC TP TC 004 safety approvals alongside BS EN/EN 55032 (CISPR 32) Class B emission compliance. In addition, built-in active PFC delivering PF > 0.95 at 230 V AC improves power quality across the 90–264 V AC / 127–370 V DC input range. Forced air cooling via an integrated DC fan manages heat dissipation, while final equipment still requires system-level EMC verification.
Lifecycle planning is backed by a minimum Telcordia SR-332 MTBF of 1,763.3k hours and a three-year manufacturer warranty covering the QP-150-3A. System integrators should account for −10 °C to +60 °C ambient operation with load derating as well as altitude derating above 2000 m. This makes the supply a practical fit for industrial controls, test rigs, and multi-voltage instruments.